At Banggood, we uses cookies and other similar technologies to provide you with essential functionalities and for aggregated statistics.
We also use optional cookies for a better experience with:
You can choose not to allow some types of cookies via"Cookie Settings".If you want to learn more about it, you can swipe to the bottom of the page to see the Privacy Policy
When you visit any website, it may store or retrieve information on your browser, mostly in the form of cookies. This information might be about you, your preferences or your device and is mostly used to make the site work as you expect it to. The information does not usually directly identify you, but it can give you a more personalized web experience.
Because we respect your right to privacy, you can choose not to allow some types of cookies. However, blocking some types of cookies may impact your experience of the site and the services we are able to offer.
{{$productInfo.reviewAmount.average}} out of 5
Press K2 and K3 to change the working mode. After selecting the working mode, press K1 to enter the time setting of A, and Axxx is displayed on the screen. At this time, press K2 and K3 to modify the time parameter of A. After setting the time of A, press K1 to set the time of B, and BXXX is displayed on the screen. At this time, press K2 and K3 to modify the time parameter of B, K2 and K3 to add and subtract 1, long press to add and subtract 1 0 quickly, and press K4 to s et the position of the decimal point. After setting the B time (if the mode has t he parameter of C cycle times), press K1 to set the number of C cycles, and the screen displays Cxxx. At this time, press K2 and K3 to modify the parameter of C cycle times, and press K2 and K3 to add and subtract 1 short and press long t o add and subtract 1 0 quickly. After setting, press K1 for the last time to exit t he setting state and save all parameters.
Table showing the position of the decimal point and its time units:
X. X is in the hundreds place, and the time range is 0.01 to 9.99 seconds The time range of xx. X is 0.1 to 99.9 seconds
XXX has no decimal point, and the time range is 1 to 999 seconds
XXX. The decimal point is in the one place. The time range is 1 to 999 minutes Off display: Press K4 key to close the display when not set. Press again to open it again.Here we need to pay attention to the state of the decimal point, many customers set wrong.
Key setting:
Working mode (32 types):
P-11: Point mode, with signal pull-in, without signal disconnection.
P-12: Self-locking mode, the state of relay is reversed once after each trigger.
P-13: After triggering, the relay pulIs and disconnects after A time delay; Invalid trigger during delay.
P-14: After triggering, the relay pulIs and disconnects after A time delay; Retiming is triggered during the delay.
P-15: After triggering, the relay pulIs and disconnects after A time delay; Accumulative timing is triggered during the delay.
P-16: After triggering, the relay pulIs and disconnects after A time delay; Reset triggered during delay (relay disconnection)
P-17: After triggering, the relay closes during the signal duration, the input signal disappears, and the relay is disconnected after A time delay; During the delay period, the relay will be triggered again to keep pulling, and the timing will stop until the last signal disappears, and the relay will be disconnected after A time delay.
P-18: After power-on, the relay immediately pulIs in then disconnects after A delay of A second; Until the next power (signal line IN+IN- no connection)
P-21: Give the signal, delay A time after the relay suction.
P-22: Give A continuous signal, after more than A time, the relay is closed; Signal lost, relay disconnected.
P-23: loss of A triple A time, relay sucking; Signal on, relay disconnected.
P-24: Give A continuous signal, after more than A time, the relay is closed; The signal disappears for more than A time, and the relay is disconnected.
P-25: Give A continuous signal, after more than A time, the relay is closed; A continuous signal is given again. After A time, the relay is disconnected.
P-26: Give the signal, and disconnect after the relay closes for A time; After the signal disappears, the relay closes again for A second and stops.
P-27: Relay with pulse signal (rising edge or falling edge) is disconnected, and there is no pulse signal. After A time delay, the relay is closed (continuous high level or continuous low level is considered as no pulse).
P-28: After power-on, the relay will be closed after A time delay until the pow er is off. (Signal line IN+IN- no connection)
P-31: After power-on, the relay closes A time and disconnects B time, with an infinite cycle; Power off stop (signal line IN+IN- no connection)
P-32: continuous signal, relay sucking time A, disconnect time B, infinite cycle; The signal disappears, terminating the loop.
P-33: Give the primary signal, the relay closes A time, disconnects B time, infinite loop; Give me one more signal to stop the loop.
P-34: After power-on, delay A time, then the relay pulls on and closes, and disconnects after B time. (Signal line IN+IN- no connection)
P-35: Give A signal, delay A time, the relay is closed, closed B time after disconnect.
P-36: Continuous signal is given. After A time, the relay is closed and disconnected after B time. The signal disappears, the timing is cleared, and the relay is disconnected.
P-37: when there is A signal, the relay will disconnect automatically after pulling off time A, and then tinning time B. Signal triggering is invalid within time A +B.
P-38: there is A signal, the relay will automatically disconnect after A time, an d then time B time, and automatically disconnect after A time.
P-41: No action on signal; Signal loss trigger; The relay disconnects after absorbing and combining delay time A.
P-42: the signal disappears and the relay closes after A time delay; The relay is disconnected after B time delay.
P-43: the signal disappears, and the relay closes after the time of disappearance exceeds A; The relay is disconnected after B time delay.
P-44: After power-on, the relay closes A time and disconnects B time; Relay disconnects and stops after cycle C (signal line IN+IN- no connection)
P-45: Does not operate after being powered on. After the signal is given, the relay closes time A and disconnects time B; After C cycles, the relay disconnects and stops; If the signal is given, it is executed again,
P-46: After feeding the signal for more than A times, the relay is closed; Keep sucking; Power cut off.
P-47: After the signal is given for more than A times, the relay is closed; Disconnect after B time of suction.
P-48: Within time C, after continuous signal feeding for more than A times, the relay will disconnect and stop after time B.
Package included:
1 x Delay Relay Module
1 x Box(optional)
Shipping method(s) | Shipping time | Tracking information |
---|